SPECIFICATIONS
Title of the
project : Auto
Door Code Lock
Domain : Embedded Systems Design
Software : Assembler, Proload
Microcontroller : 89S52 CISC Micro Controller
Power Supply : +5V, 500mA Regulated Power Supply
Display : a)
LCD, HD44780 16-character, 2-line (16X2)
b)
LED 5mm
Crystal : 11.0592MHz
Sensors : Tactile switches
Applications : Homes, offices, shops etc
ABSTRACT
Security is
a prime concern in our day-today life. Everyone wants to be as much secure as
possible. An access control for doors forms a vital link in a security chain. The microcontroller based digital lock for Doors is an access control system that
allows only authorized persons to access a restricted area. The system is fully
controlled by the 8 bit microcontroller AT89S52 which has a 8Kbytes of ROM for
the program memory. The password is stored in the EPROM so that we can change
it at any time. The system has a Keypad by which the password can be entered
through it. When the entered password equals with the password stored in the
memory then the motor gets activated so that the door is opened. If we entered
a wrong password a buzzer is switched on and error is indicated. The user is
required to entered the code again ater some delay
Working:
The step-down transformer converts the 230V ac to 12V AC. The
output of the transformer is connected to bridge rectifier. It converts 12V ac
to pulsating DC voltage. It is rectified with the help of capacitor filter so
that ripples are removed and smooth DC voltage is obtained at the output.
Microcontroller requires constant Dc voltage of +5Volts for its proper
functioning. It is obtained using a positive constant voltage regulator 78XX.it
provides constant voltage output irrespective of voltage variations at the
input or load current.
There are 4 keys which are connected to the microcontroller ports.
The microcontroller continuously scans the keys. When the user enters the key
code the system compares the user’s input with the code stored in the memory.
If there is a match it opens the door. The door opening is realized using a
motor connected to the door. In case of error in code entry the access is
denied and an audio indication of 3 beeps are generated. The user can enter the
code again only after some delay.
This project
uses regulated 5v, 500mA power supply. 7805, a three terminal voltage regulator
is used for voltage regulation. Bridge type full wave rectifier is used to rectify the ac output of secondary of
230/12v step down transformer.
BLOCK DIAGRAM
Keep Visiting for more Updates
Thanks n regards,
ADMIN Examsadda